No products
View larger
New product
This standard applies to portable devices for household and similar uses hereafter referred to as portable residual current devices (PRCDs) consisting of a plug, a residual current device (RCD) and one or more socket-outlets or a provision for connection, functionally independent of, or functionally dependent on, line voltage. They do not incorporate overcurrent protection. They are intended for single-phase circuits for rated currents not exceeding 16 A for rated voltages not exceeding 250 V a.c. They are intended to provided protection against shock hazard in case of direct contact, in addition to the protection provided by the fixed installations for the circuit downstream.
| Author | VDE |
|---|---|
| Editor | VDE |
| Document type | Standard |
| Format | Paper |
| Cancellation date | |
| Confirmation date | |
| expiration_de_validite | |
| ICS | 29.120.50 : Fuses and other overcurrent protection devices
|
| Number of pages | 141 |
| Replace | DIN VDE 0661-10 (2002-12) |
| Cross references | HD 639 S1 (2002-03), IDT |
| Modified by | DIN VDE 0661-10/A2 (2011-01)
|
| Weight(kg.) | 0.3397 |
| Year | 2004 |
| Document history | DIN VDE 0661-10 (2004-06) |
| Country | Germany |
| Keyword | DIN VDE 0661;0661 |