New product
1.1 This test method covers the quantitative determination of total sulfur in gasoline and gasoline-oxygenate blends. The Pooled Limit of Quantitation (PLOQ) was determined to be 15 mg/kg. Therefore, the practical range for this test method is from 15 mg/kg to 940 mg/kg.
Note 1: This concentration range is based on that used in the interlaboratory round robin, which shows that the range of sulfur in the round robin samples was from 1.5 mg/kg to 940 mg/kg; however, below 15 mg/kg, the reproducibility approaches 100 % of the concentration.