1.1 This test method covers the X-ray fluorescence spectrometric analysis of low-alloy steels and cast irons for the following elements in the ranges indicated:
| Elements | Mass Fraction Range, % | |
| Manganese | 0.20 to 1.50 | |
| Nickel | 0.10 to 1.00 | |
| Chromium | 0.10 to 1.00 | |
| Molybdenum | 0.04 to 0.40 | |
| Copper | 0.05 to 0.30 | |
| Vanadium | 0.03 to 0.25 |
Note 1—These mass fraction ranges can be extended by the use of suitable reference materials. The detection limit for the elements is lower than the listed minimum value. The ranges represent the actual levels at which this test method was tested.
1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Significance and Use: