This clause of part 1 is replaced by the following:
This part of IEC 61496 specifies requirements for the design,
construction and testing of ELECTRO-SENSITIVE PROTECTIVE EQUIPMENT
(ESPE) for the safeguarding of machinery, employing ACTIVE
OPTO-ELECTRONIC PROTECTIVE DEVICES (AOPDS) for the sensing
function. Special attention is directed to features that ensure an
appropriate safety-related performance is achieved. An ESPE may
include optional safety-related functions, the requirements for
which are given in annex A of part 1.
This part does not specify the dimensions or configurations of
the detection zone and its disposition in relation to hazardous
parts for any particular application, nor what constitutes a
hazardous state of any machine. It is restricted to the functioning
of the ESPE and how it interfaces with the machine.
Excluded from this part are AOPDS employing radiation at
wavelengths outside the range 400 nm to 1 500 nm.
This part may be relevant to applications other than those for
the protection of persons, for example the protection of machinery
or products from mechanical damage. In those applications
additional requirements may be necessary, for example when the
materials that are to be recognized by the sensing function have
different properties from those of persons.
This part does not deal with EMC emission requirements.