Description / Abstract:
These requirements cover concentrator photovoltaic (CPV) modules
and assemblies that concentrate light on a target PV cell(s) for
use in general and restricted areas in accordance with the unit's
installation instructions. A CPV module is defined as any
photovoltaic module which uses artificially elevated levels (i.e.
concentrated) of solar irradiance to produce electrical energy.
These requirements address concentrator photovoltaic (CPV)
modules and assemblies intended for installation in accordance with
their installation instructions on or integral with buildings, or
to be freestanding (i.e. ground mounted or otherwise not attached
to buildings), in accordance with the National Electrical Code,
NFPA 70, and model building codes.
The installation class for CPV modules and assemblies identifies
the intended installation location as either general access areas
designated "General," or restricted access areas designated
"Restricted." General access units are able to be installed in open
areas that may be contacted by the general public. Restricted
access units are to be installed in areas that prevent general
public access such as a locked and fenced in area.
These requirements cover CPV modules and assemblies intended for
use in systems with a maximum system voltage of 1500 V.
Exception: CPV modules that are constructed in the flat
plate module format as defined by the Standard for Flat-Plate
Photovoltaic Modules and Panels, UL 1703, and with a concentration
ratio of no more than 3 times shall be evaluated in accordance with
all of the requirements in UL 1703.