Description / Abstract:
This guide contains instructions for conducting generally
applicable and accepted tests to determine the performance
characteristics of synchronous machines. Although the tests
described are applicable in general to synchronous generators,
synchronous motors (larger than fractional horsepower), synchronous
condensers, and synchronous frequency changers, the descriptions
make reference primarily to synchronous generators and synchronous
motors. The tests described may be applied to motors and
generators, as needed, and no attempt is made to partition this
guide into clauses applying to motors and clauses applying to
generators. It is not intended that this guide shall cover all
possible tests or tests of a research nature, but only general
methods that may be used to obtain performance data. The schedule
of factory and field tests, which may be required on new equipment,
is normally specified by applicable standards or by contract
specifications. This guide should not be interpreted as requiring
any specific test in a given transaction or implying any guarantee
about specific performance indices or operating conditions.
The term specified conditions for tests as used in this
guide will be considered as rated conditions unless otherwise
agreed upon. Rated conditions apply usually to the quantities
listed on the machine nameplate.