More info
Description / Abstract:
This Standard establishes the requirements for functional
qualification of power operated active valve assemblies for nuclear
power plants. It is not intended that this Standard be applied to
power operated relief valves and self-operated valves such as check
and pressure relief valves. It is the responsibility of the plant
owner or his designee to identify those active valves which require
qualification under this Standard and to identify the functional
qualification requirements, as associated with Annexes A through H,
which shall be met.
Functional qualification of a parent valve assembly consists of
testing as specified herein to demonstrate that a valve assembly
can perform its required function under test conditions. Annex J is
a guide to provide functional qualification of a candidate valve
assembly by analyses that demonstrate design similarity to a parent
valve assembly. Any use of Annex J for qualification of a candidate
valve for a specific application in a nuclear power plant shall be
the responsibility of the plant owner or his designee.
Qualification testing, inspecting, and reportingas
specified herein shall beperformance in accordancewith
the applicable requirements of ANWASME NQA-1 or its equivalent.
A Functional Qualification Reports(s) is required to document
compliance with this Standard. An Application Report(s) is required
to document qualification of a valv assembly for a specific nuclear
plant application.